Compressor A Analysis
Executive Summary
High VibrationDue to unexpectedly high vibration levels in Compressor A, a comprehensive vibration analysis was conducted. The overall RMS vibration exceeded the alarm limit of 7.1 mm/s (ISO 10816-3). Analysis identifies shaft imbalance and system resonance as primary contributors.
2-Year Vibration History
Vibration Trend (Run-up / Coast-down)
Key Measurements
- RMS Velocity (Overall) 8.2 mm/s
- Peak (1X) Axial MDE 6.61 mm/s
- Peak (1X) Horiz PDE 4.88 mm/s
- Resonant Peak (1015 RPM) 26.69 mm/s
Contributing Factors
Recommendations
Avoid operating at speeds that excite resonant frequencies (approx. 70% and 90% of rated speed). Lock out 1015 RPM range in VFD.
Reinforce motor base frame with stiffeners to shift natural frequencies away from operating range.
Perform motor solo run test. If imbalance confirmed, perform field balancing of the rotor.